Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 60-70%


POTASSIUM CARBONATE

CAS: 584-08-7

RTECS: TS7750000

Fraction By Weight: 25-35%


POTASSIUM HYDROXIDE

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 1-5%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


POTASSIUM BROMIDE

CAS: 7758-02-3

RTECS: TS7650000

Fraction By Weight: <1%


PHOSPHONIC ACID,(1-HYDROXYETHYLIDENE)DI-

CAS: 2809-21-4

RTECS: SZ8562100

Fraction By Weight: <1%

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPECTED TO BE A LOW
HAZARD FOR RECOMMENDED HANDLING. EYES: CAUSES BURNS. SKIN: CAUSES
IRRITATION. INGESTION: MAY CAUSE BURNS OF THE GASTROINTESTINAL
TRACT IF SWALLOWED.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION-MOVE TO FRESH AIR. TREAT SYMPTOMATICALLY. GET
MEDICAL ATTENTION IF SYMPTOMS PERSIST. EYES-IMMEDIATELY FLUSH WITH
PLENTY OF WATER FOR 15 MIN. GET MEDICAL ATTENTION. SKIN-IMMEDIATELY
REMOVE S OILED CLOTHES/SHOES & WASH WITH SOAP & WATER. GET MEDCIAL
ATTENTION. INGESTED-DO NOT INDUCE VOMITING. GIVE VICTIM A GLASS OF
WATER. CALL A PHYSICIAN OR POISON COTROL CENTER IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. MAY REQUIRE
NEUTRALIZATION IF PH <2 OR >12.5. FLUSH TO SEWER WITH LARGE AMOUNTS
OF WATER. OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT
MATERIAL, THEN PLACE I N A CONTAINER FOR CHEMICAL WASTE.
CLEANSURFACE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM INCOMPATIBLE
SUBSTANCES. KEEP CONTAINER CLOSED.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:WEAR IMPERVIOUS GLOVES FOR THE RISK.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELD.
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES.
Work Hygienic Practices:GOOD INDUSTRIAL HYGIENE PRACTICES TO MINIMIZE
SKIN CONTACT AND INHALATION.
Supplemental Safety and Health
CORROSIVE.

Chemical Properties

HCC:C2
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.37
pH:>13
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, ODORLESS.
Percent Volatiles by Volume:60-70

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS.
Stability Condition to Avoid:STABLE.
Hazardous Decomposition Products:NONE
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE
AMOUNTS OF WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.